Frequently Asked Question
Sample
-M150054 => %R-M150054 (Every "-" add %R)
PXXHNRP4ZU => %PXXHNRP4ZU (Others add %P)
Purpose
1. We need to set up rules for "-" to output % R
2. Others output add "%P"
Steps
Go to https://scanmaster.cipherlab.com/
Select your Device => Output Format => Data Editing
1.
For "%R" : Format1 =>Edit => (Matching:[-], Matching String Location : 1) =>
Field Setting =>(Additional1 setting (%R), transmission sequence:[A1][F1] =>OK
2.
For ''%P" : Format2 =>Edit =>Field Setting
=>(Additional1 setting (%P), transmission sequence:[A1][F1] =>OK
And then generate as 2D Code
#PS
Restore System Defaults - Restores all settings on the device, erasing any previous settings.
Non-Restore System Defaults - Adds the new setting without restoring or affecting the existing settings on the device.